Sequence Output Terminal Assignment And Monitoring; Assignment Of Sequence Output; Sequence Output Monitor - GE VAT2000 Instruction Manual

Ac speed control equipment
Hide thumbs Also See for VAT2000:
Table of Contents

Advertisement

5-6-2 Sequence output terminal assignment and monitoring

The ON/OFF of the internal signals can be output to the RA-RC and PSO1 to 3-PSOE terminals as
shown in Fig. 5-5 with the parameter Nos. C13-2 to 5 and C33. The ON/OFF of each signal can be
monitored as shown in Fig. 5-6. This monitoring is executed with D04-3, 4.
Internal
Signal
R U N
0
FLT
1
M C
2
R D Y 1
3
R D Y 2
4
L C L
5
R E V
6
ID E T
7
ATN
8
S P D 1
9
S P D 2
1 0
C O P
11
E C 0
1 2
E C 1
1 3
E C 2
1 4
E C 3
1 5
A C C
1 6
D C C
1 7
A U X D V
1 8
A L M
1 9
FA N
2 0
A S W
2 1
ZS P
2 2
L LM T
2 3
U L M T
2 4
Fig. 5-5 Assignment of sequence output
5. Control Input / Output
Term inal
board
P S O
FA
(O u tp ut
fixe d )
FB
FC
R A
C 1 3 -2 = 0
R C
C 1 3 -3 = 3
P S O 1 -3
C 1 3 -4 = 7
C 1 3 -5 = 8
P S O E
P S O 4
P S O 5
P S O 4
P S O 5
E C 3
ID E T
L LM T
Fig. 5-6 Sequence output monitor
5-10
E C 2
E C 1
E C 0
C O P
S P D 2
S P D 1
ATN
R U N
FLT
M C
R D Y 1
R D Y 2 L
L C L
R E V
(D04-3 display)
U L M T
A C C
D C C
A U X D V
A L M
FA N
A S W
ZS P
(D04-4 Display)