5-8 Programmable analog output function (PAO)

5-8-1 Types of analog outputs

As a standard, there are two programmable analog outputs (10 bits) in the VAT2000, with terminal board
numbers FM-COM, and AM-COM. Two more analog outputs are available by the optional PCB
U2KV23TR0 (Trace Back option).
Each output can be programmed with the internal functions shown in Fig. 5-8. As default, FM is assigned
as "output frequency" and AM is assigned as "Motor output current".

5-8-2 Setting the analog output

The following internal data or functions can be output to FM, AM terminals by parameters C13-0 and C13-
1 as shown in Fig. 5-8.
The extended analog outputs AO1 and AO2, can be addressed with the internal data by parameters C39-
0 and C39-1.
If needed, the gain of analog outputs can be adjusted by parameters C14-0, C14-1.
S e tting fre qu e ncy (S e ttin g sp e ed )
5. Control Input / Output
Default settings
Terminal symbol
FM
AM
Internal Data
O utpu t freq ue ncy
C u sh io n ou tpu t
O utpu t cu rren t (M o to r)
O utpu t cu rren t (D rive)
O utpu t vo lta ge
O utpu t P ow e r (D rive )
D C vo lta ge
O LT M o nito r
H e at sink te m pe rature
M otor S pe ed
Fig. 5-8 Analog output assignment
Setting
Output frequency
Output current (Motor)
PAO
C 1 3-0 =0
0
1
C 1 3-1 =3
2
3
4
(C 3 9-0 )
5
6
(C 3 9-1 )
7
8
U 2 K V 2 3T R O O ption
9
1 0
5-13
Term inal block
FM
A M
A O 1
A O 2

Hide quick links: