Torque Setting; Torque Setting Selection; Torque Setting Selection Sequence - GE VAT2000 Instruction Manual

Ac speed control equipment
Hide thumbs Also See for VAT2000:
Table of Contents

Advertisement

5-9-2 Torque setting

(1) Torque setting selection

The torque setting in VAT2000 is possible from either analog signals, serial communications or from
the operation panel. All these are selectable by the user.
Setting
input point
Analog
Analog torque setting
Serial
Serial torque setting
Panel
Panel torque setting

(2) Torque setting selection sequence

The torque setting interlock sequence is shown below.
A n alog Torq ue se ttin g
(C 0 7-6 )
S e ria l co m m u nica tion
Torq ue settin g
O pe ra tio n P an e l
Torqu e se tting
(B 1 3-0)
5. Control Input / Output
Setting data
The torque setting is possible from the analog input.
The torque setting is allowed from a host computer with
serial transmission.
A serial interface option type U2KV23SL0 is required.
The torque setting is allowed by parameter (B13-2).
X X X
o ff
o n
Fig. 5-10 Torque setting selection
Explanation
Fu nction s that can b e co ntrolled O N / OFF
from term inal board
C FS
L C L
o ff
o n
5-15
Fo rw a rd R un
C 0 2-2
=1
Torq ue settin g
-1
R e ve rse R un
=2
=3
=4

Hide quick links: