Menu Descriptions; Setup Menu - Rice Lake IQ plus 310A Installation Manual

Digital weight indicator
Hide thumbs Also See for IQ plus 310A:
Table of Contents

Advertisement

3.3 MENU DESCRIPTIONS

3.3.1 SETUP MENU

NOTE: Factory default settings are shown in bold type with a
parentheses beneath each parameter name is the EDP command for that parameter.
NAME/CODE
DESCRIPTION
GRADS
Specifies number of full scale graduations. Value should be consis-
(GR)
tent with legal requirements and environmental limits on the useful
system resolution.
DEC PNT
Determines location of decimal point or dummy zeros. Code 6 has
(DP)
no decimal point. Codes 7 and 8 have no decimal point and one
and two dummy zeros respectively. Value should be consistent with
legal requirements. This number may be modified automatically by
the indicator when the UNITS key (or equivalent EDP command) is
used to display alternate units.
DSP DIV
Specifies display division size—the number that GRADS are multi-
(DD)
plied by to give the displayed weight. This number is equal to the full
scale capacity divided by the number of full scale graduations. This
number may be modified automatically by the indicator when the
UNITS key (or equivalent EDP command) is used to display alternate
units.
UNITS
Specifies the units for displayed and printed weight.
(UN)
DFILT1
Sets each of the three digital filter stages to a value representing the
(F1)
number of A/D readings over which an average is calculated. Set-
ting DFILT1 automatically sets DFILT2 and DFILT3 to the same
DFILT2
value unless DFILT2 and DFILT3 are then changed independently to
(F2)
achieve intermediate values. The lowest value (OFF-OFF-OFF)
DFILT3
provides the quickest response. The higher the number, the heavier
(F3)
the digital filtering and slower the response time.
Filtering values may be modified via EDP commands in either
SETUP or OPERATING modes.
See Section 7.2 for more complete information on setting digital
filtering.
Filter cutout threshold. Selects the threshold, in display divisions,
DF THRH
beyond which the digital filtering will cut out. If a specified number
(FL)
(see DF SENS) of consecutive readings are outside the specified
threshold around the currently displayed value, the indicator will jump
immediately to the most recent value, ignoring filtering.
"NONE" disables threshold checking.
18
F1
F2
F3
OFF OFF OFF
No Filtering
2
2
2
4
4
4
8
8
8
16
16
16
32
32
32
64
64
64
128
128
128
256
256
256
Heaviest Filtering
. The two-letter code in
CODE/VALUE
0 to 60,000
Default = 10,000
0 = 8.888888
1 = 88.88888
2 = 888.8888
3 = 8888.888
4 = 88888.88
5 = 888888.8
6 = 8888888
7 = 8888880
8 = 8888800
0 = 1
1 = 2
2 = 5
0=LB
4=GRAM
1=KG
5=GRAIN
2=TON
6=OZ
3=T*
7=NONE
*(metric)
0 = OFF
1 = 2
2 = 4
3 = 8
4 = 16
5 = 32
6 = 64
7 = 128
8 = 256
0 = NONE
1 = 2 DD
2 = 5 DD
3 = 10 DD
4 = 20 DD
5 = 50 DD
6 = 100 DD
7 = 200 DD
8 = 250 DD
Continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents