Front Panel Configuration; Menu Structures And Parameter Descriptions - Rice Lake 920i Installation Manual

Programmable weight indicator and controller
Hide thumbs Also See for 920i:
Table of Contents

Advertisement

3.1.3
Front Panel Configuration
Use the CONFIG submenu under the SCALES menu
to conÞgure A/D scales. For example, in an indicator
with a single-channel A/D card installed in Slot 1, the
Scale ConÞguration display will show the A/D listed
(
) under the
Slot 1 Channel 1
Use the
navigation key to select the A/D, then
left
press the center softkey,
to the Associated A/DÕs column. If no other A/DÕs are
listed in the
AVAILABLE A/D's
softkey changes to
Done
Press
to exit the Scale ConÞguration display.
Done
See Section 10.4 on page 97 for information about
conÞguring serial scales.
The
920i
indicator can be conÞgured using a series of menus accessed through the indicator front panel when the
indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.
Menu
SCALES
Configuration
SERIAL
Serial
FEATURE
Feature
PFORMT
Print Format
SETPTS
Setpoints
DIG I/O
Digital I/O
ALGOUT
Analog Output
VERSION
Version
3.2

Menu Structures and Parameter Descriptions

The following sections provide graphic representations of the
menu parameters. Default values are shown in bold type; numeric ranges and string values are shown in italic
type. Parameters shown surrounded by a dotted-line box only appear under the special circumstances explained
under each box.
SCALES
SERIAL
column.
AVAILABLE A/D's
Add
. The A/D is then moved
column, the center
, as shown in Figure 3-2.
Configure and calibrate scales.
Configure communications ports.
Set date and time formats, truck mode, passwords, keyboard locks, regulatory mode, and
initial consecutive number value, define softkeys and setpoint prompts.
Set print format used for header, gross, net, truck in/out, setpoint, and auxiliary ticket formats.
See Section 6.0 on page 53 for more information.
Configure setpoints and batching mode.
Assign digital input/output functions.
Configure analog output module. Used only if analog output option is installed.
Display installed software version number. The Reset Config softkey on the Version menu can
be used to restore all configuration parameters to their default values.
Table 3-1. 920i Menu Summary
FEATURE
PFORMT
Figure 3-3. ConÞguration Menu Flow
Figure 3-2. Scale ConÞguration Display
Menu Function
menu structures and tables describing the
920i
SETPTS
DIG I/O
ALGOUT
VERS
Shown only if
Analog Ouptut
card is installed
Configuration
21

Advertisement

Table of Contents
loading