6.4 SERIAL PORT OPERATION AND DATA FORMATS (CONTINUED)
<STX> <SWA> <SWB> <SWC> <wwwwww> <tttttt> <EOL> <CHK>
STX (02h)
Status Word A
7-digit gross or net weight, right justified, padded with
leading spaces. Decimal points are not transmitted.
Status Word A:
7
6
5
Parity
0
1
MUL1 MUL0 DP2
Even parity bit.
Requires EDP Port setup.
See Section 3.3.3.
Disp. Div.
MUL1 MUL0 Multiplier
0 1 x 1
1 0 x 2
1 1 x 5
Status Word B:
7
6
5
Parity
0
1
Even parity bit:
Requires EDP Port
setup. See Section
3.3.3.
0 = lb
1 = kg
Status Word C: ASCII 20h (space)
7
6
5
Parity
0
1
Even parity bit:
Requires EDP Port setup. See Section 3.3.3.
FIGURE 25 – TOLEDO T8142 AND T8142CK FORMATS
Status Word B
Status Word C
4
3
2
1
0
DP1
DP0
DP2 DP1 DP0 Fixed Zero/Dec. Pt. Location
0 0 0 x 100
(2 fixed zeroes)
0 0 1 x 10
(1 fixed zero)
0 1 0 x 1
(No decimal point)
0 1 1 x 0.1
(1 decimal place)
1 0 0 x 0.01
(2 decimal places)
1 0 1 x 0.001
(3 decimal places)
1 1 0 x 0.0001 (4 decimal places)
1 1 1 x 0.00001 (5 decimal places)
4
3
2
1
0
0 = Positive indicated weight value
1 = Negative indicated weight value
0 = In range
1 = Out of range
0 = Stable
1 = Motion
4
3
2
1
0
0
0
0
0
0
<CR>
Six-digit tare weight. Dummy zeroes are
transmitted, decimal points are not. Characters are
always right justified, padded with leading zeroes,
except when the gross weight is negative, in
which case all characters are spaces.
0 = Gross Display Mode
1 = Net Display Mode
For T8142CK
Format Only:
Optional Checksum
Character
33