Rice Lake IQ plus 310A Installation Manual page 38

Digital weight indicator
Hide thumbs Also See for IQ plus 310A:
Table of Contents

Advertisement

Power
AC Option:
Line Voltages
115 VAC (102-132) and 230 VAC (207-253)
Frequency
50 or 60 Hz
Power Consumption
12 VA maximum
Fusing
115 VAC: 2 x 0.25A SB (UL/CSA) 5x20mm
230 VAC: 2 x T 125 mA (IEC127) 5x20mm
Environmental
OIML
Meets OIML Document No. 11 Climatic, Mechanical, and Electrical requirements
Operating Temperature
–10 to +40°C (legal operating range)
–10 to +50°C (industrial operating range)
Storage Temperature
–25 to +70°C
Electric Field Rejection
3V/m for 100 kHz to 1 GHz, ≤ 1 uV susceptibility
Emissions
FCC Part 15 Class A, UL 466, UL 508 and CISPR 22 Class A
Electrical Safety
According to IEC 950, UL 1950, CSA 950
Mechanical
Overall Dimensions
196.9 mm (7.75 in)W x 121.9 mm (4.80 in)H
x 129.5 mm (5.10 in)D
Panel Cutout
186.0 mm (7.375 in) W x 114.3 mm (4.50 in) H
Bezel
196.9 mm (7.75 in) W x 121.9 mm (4.80 in) H
Depth Behind Panel
116.8 mm (4.6 in) (Excluding cables)
Weight
2.61 kg (5.75 lb)
Materials
Painted aluminum bezel, painted steel case, and aluminum rear panel
Mounting Options
Adjustable angle wall/bench mount standard
Panel mount optional