Global Protection Parameters of the System

Parameter
Description
PSet-Switch
Switching Parameter Set
PS1: Activated by
This Setting Group will be the active one if: The
Parameter Setting Group Switch is set to "Switch via
Input" and the other three input functions are inactive at
the same time. In case there is more than one input
function active, no Parameter Setting Group Switch will
be executed. In case all input functions are inactive, the
device will keep working with the Setting Group that was
activated lastly.
Only available if: PSet-Switch = PSS via Inp fct
PS2: Activated by
This Setting Group will be the active one if: The
Parameter Setting Group Switch is set to "Switch via
Input" and the other three input functions are inactive at
the same time. In case there is more than one input
function active, no Parameter Setting Group Switch will
be executed. In case all input functions are inactive, the
device will keep working with the Setting Group that was
activated lastly.
Only available if: PSet-Switch = PSS via Inp fct
PS3: Activated by
This Setting Group will be the active one if: The
Parameter Setting Group Switch is set to "Switch via
Input" and the other three input functions are inactive at
the same time. In case there is more than one input
function active, no Parameter Setting Group Switch will
be executed. In case all input functions are inactive, the
device will keep working with the Setting Group that was
activated lastly.
Only available if: PSet-Switch = PSS via Inp fct
PS4: Activated by
This Setting Group will be the active one if: The
Parameter Setting Group Switch is set to "Switch via
Input" and the other three input functions are inactive at
the same time. In case there is more than one input
function active, no Parameter Setting Group Switch will
be executed. In case all input functions are inactive, the
device will keep working with the Setting Group that was
activated lastly.
Only available if: PSet-Switch = PSS via Inp fct
EMR-4000
Setting range
PS1,
PS2,
PS3,
PS4,
PSS via Inp fct,
PSS via Comm
1..n, PSS
1..n, PSS
1..n, PSS
1..n, PSS
www.eaton.com
IM02602009E
Default
Menu path
PSS via Inp fct
[Protection Para
/PSet-Switch]
Sys.Maint Mode
[Protection Para
Inactive
/PSet-Switch]
Sys.Maint Mode
[Protection Para
Active
/PSet-Switch]
-.-
[Protection Para
/PSet-Switch]
-.-
[Protection Para
/PSet-Switch]