Eaton EMR-4000 Installation, Operation And Maintenance Manual page 940

Motor relay
Table of Contents

Advertisement

Name
Bkr.Res Isum trip
Bkr.WearLevel Alarm
Bkr.WearLevel Lockout
Bkr.Res Bwear Curve
Bkr.Isum Intr ph Alm
Bkr.Res Isum Intr ph Alm
MStart.Active
MStart.Blo TripCmd
MStart.Trip
MStart.TripCmd
MStart.Start
MStart.Run
MStart.Stop
MStart.Blo
MStart.NOCSBlocked
MStart.SPHBlocked
MStart.SPHBlockAlarm
MStart.TBSBlocked
MStart.ThermalBlock
MStart.RemBlockStart
MStart.TransitionTrip
MStart.ZSSTrip
MStart.INSQSP2STFaill
MStart.INSQSt2RunFail
MStart.LATBlock
MStart.ColdStartSeq
MStart.ForcedStart
MStart.TripPhaseReverse
MStart.EmergOverrideDI
MStart.EmergOverrideUI
MStart.ABKActive
MStart.GOCStartBlock
MStart.IOCStartBlock
MStart.ULoadStartBlock
Description
Signal: Reset summation of the tripping currents
Signal: Breaker Wear curve Alarm
Signal: Breaker Wear Curve Lockout Level
Signal: Reset of the Breaker Wear maintenance curve.
Signal: Alarm, the per hour Sum (Limit) of interrupting currents has been exceeded.
Signal: Reset of the Alarm, "the per hour Sum (Limit) of interrupting currents has been exceeded".
Signal: Active
Signal: Trip Command blocked
Signal: Trip
Signal: Trip Command
Signal: Motor is in start mode
Signal: Motor is in run mode
Signal: Motor is in stop mode
Signal: Motor is blocked for starting or transition to Run mode
Signal: Motor is prohibited to start due to number of cold start limits
Signal: Motor is prohibited to start due to starts per hour limits
Signal: Motor is prohibited to start due to starts per hour limits, would come active in the next stop
Signal: Motor is prohibited to start due to time between starts limits
Signal: Thermal block
Signal: Motor is prohibited to start due to external blocking through digital input DI
Signal: Start transition fail trip
Signal: Zero speed trip (possible locked rotor)
Signal: Fail to transit from stop to start based on reported back time
Signal: Fail to transit from start to run based on reported back time
Signal: Long acceleration timer enforced
Signal: Motor cold start sequence flag
Signal: Motor being forced to start
Signal: Relay tripped because of phase reverse detection
Signal: Emergency override start blocking through digital input DI
Signal: Emergency override start blocking through front panel
Signal: Anti-backspin is active. For certain applications, such as pumping a fluid up a pipe, the motor may be
driven backward for a period of time after it stops. The anti-backspin timer prevents starting the motor while it
is spinning in the reverse direction.
Signal: Ground Instantaneous Overcurrent Start Delay. GOC (Instantaneous Overcurrent) elements are
blocked for the time programmed under this parameter
Signal: Phase Instantaneous Overcurrent Start Delay. IOC (Instantaneous Overcurrent) elements are blocked
for the time programmed under this parameter
Signal: Underload Start Delay. Underload(Instantaneous Overcurrent) elements are blocked for the time
programmed under this parameter
www.eaton.com
EMR-4000
IM02602009E
940