Eaton EMR-4000 Installation, Operation And Maintenance Manual page 973

Motor relay
Table of Contents

Advertisement

Name
IEC61850.VirtOut19-I
IEC61850.VirtOut20-I
IEC61850.VirtOut21-I
IEC61850.VirtOut22-I
IEC61850.VirtOut23-I
IEC61850.VirtOut24-I
IEC61850.VirtOut25-I
IEC61850.VirtOut26-I
IEC61850.VirtOut27-I
IEC61850.VirtOut28-I
IEC61850.VirtOut29-I
IEC61850.VirtOut30-I
IEC61850.VirtOut31-I
IEC61850.VirtOut32-I
IRIG-B.Active
IRIG-B.Inverted
IRIG-B.Control Signal1
IRIG-B.Control Signal2
IRIG-B.Control Signal4
IRIG-B.Control Signal5
IRIG-B.Control Signal6
IRIG-B.Control Signal7
IRIG-B.Control Signal8
IRIG-B.Control Signal9
IRIG-B.Control Signal10
IRIG-B.Control Signal11
IRIG-B.Control Signal12
IRIG-B.Control Signal13
IRIG-B.Control Signal14
IRIG-B.Control Signal15
IRIG-B.Control Signal16
IRIG-B.Control Signal17
IRIG-B.Control Signal18
SNTP.SNTP active
Statistics.ResFc all
Statistics.ResFc I Demand
Statistics.ResFc P Demand
Description
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Module input state: Binary state of the Virtual Output (GGIO)
Signal: Active
Signal: IRIG-B inverted
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: IRIG-B Control Signal
Signal: If there is no valid SNTP signal for 120 sec, SNTP is regarded as inactive.
Signal: Resetting of all Statistic values (Current Demand, Power Demand, Min, Max)
Signal: Resetting of Statistics - Current Demand (avg, peak avg)
Signal: Resetting of Statistics - Power Demand (avg, peak avg)
www.eaton.com
EMR-4000
IM02602009E
973