Shift the transmission to the neutral position, turn the ignition
switch to the ON position.
Press the starter button and allow the engine to turn for a few
seconds, and then measure the pickup coil peak voltage.
Repeat the above procedure a few times and measure the
highest pickup coil peak voltage.
# Pickup coil peak voltage: 4.0 V and more
( Tester knob indication: Voltage (&)
If the peak voltage measured on the CDI unit coupler is lower
than the standard value, measure the peak voltage on the gen-
erator coupler as follows:
Remove the left fuel tank side cover. (!7-5)
Disconnect the generator coupler and connect the multi circuit
tester with the peak volt adaptor as follows.
Pickup coil: + Probe...Green/White lead wire
- Probe...Blue/Yellow lead wire
Measure the pickup coil peak voltage in the same manner as on
the CDI unit coupler.
# Pickup coil peak voltage: 4.0 V and more
( Tester knob indication: Voltage (&)
If the peak voltage on the generator coupler is within the specifi-
cation, but on the CDI unit coupler is not within specification,
replace the wire harness with a new one. If both peak voltages
are out of specification, replace the generator with a new one.
PICKUP COIL RESISTANCE
Remove the left fuel tank side cover. (!7-5)
Disconnect the generator coupler.
Measure the resistance between the lead wires using the multi
circuit tester. If the resistance is not within the specified value,
stator coil must be replaced.
# Pickup coil resistance: 80
$ 09900-25008: Multi circuit tester set
( Tester knob indication: Resistance (Ω Ω Ω Ω )
155 Ω Ω Ω Ω (B/Y
G/W)
ELECTRICAL SYSTEM
Peak volt adaptor
B/Y
G/W
Generator
Pickup coil
8-21