Range
300 mV
20 to 50 Hz
50 to 150 Hz
150 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
3 V
20 to 50 Hz
50 to 150 Hz
150 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz
30 V
20 to 50 Hz
50 to 150 Hz
150 Hz to 10 kHz
10 kHz to 20 kHz
20 kHz to 50 kHz
50 kHz to 100 kHz, V<20V
150/300 V
20 to 50 Hz
50 to 150 Hz
150 Hz to 2 kHz
Vx Hz<2 x10
2 kHz to 20 kHz, V<100V
20 kHz to 50 kHz, V<40V
[1] Sinewave inputs>6% of scale and signals with crest factors <2.
A-10
Table A-12. PAI Module AC Voltage Accuracy Specifications
Frequency
6
1 Year Accuracy + (%input + V) [1]
18 °C to 28 °C
Slow
Fast
3%+.25 mV
6%+.5 mV
0.4%+.25 mV
1%+.5 mV
0.3%+.25 mV
1%+.5 mV
0.4%+.25 mV
1%+.5 mV
2%+.3 mV
3%+.5 mV
5%+.5 mV
5%+1 mV
3%+2.5 mV
6%+5 mV
0.4%+2.5 mV
1%+5 mV
0.3%+2.5 mV
1%+5 mV
0.4%+2.5 mV
1%+5 mV
1%+3 mV
1.5%+6 mV
2%+5 mV
3%+10 mV
3%+25 mV
6%+50 mV
0.4%+25 mV
1%+50 mV
0.3%+25 mV
1%+50 mV
0.4%+25 mV
1%+50 mV
1%+30 mV
1.5%+60 mV
2%+50 mV
3%+100 mV
3%+.25 V
6%+.5 V
0.4%+.25 V
1%+.5 V
0.3%+.25 V
1.2%+.5 V
0.4%+.25 V
1.6%+.5 V
1%+.30 V
2.0%+.6 V
-10 °C to 60 °C
Slow
Fast
3.5%+.25 mV
7%+.5 mV
0.5%+.25 mV
1.5%+.5 mV
0.4%+.25 mV
1.5%+.5 mV
0.7%+.25 mV
1.5%+.5 mV
3%+.3 mV
4%+.5 mV
7%+.5 mV
8%+1 mV
3.5%+2.5 mV
7%+5 mV
0.5%+2.5 mV
1.2%+5 mV
0.4%+2.5 mV
1.2%+5 mV
0.5%+2.5 mV
1.2%+5 mV
1.5%+3 mV
2%+6 mV
3%+5 mV
4%+10 mV
3.5%+25 mV
7%+50 mV
0.5%+25 mV
1.2%+40 mV
0.5%+25 mV
1.2%+40 mV
0.5%+25 mV
1.2%+40 mV
1%+30 mV
2%+50 mV
2.5%+50 mV
4%+100 mV
3.5%+.25 V
7%+.5 V
0.5%+.25 V
1.2%+.4 V
0.5%+.25 V
1.4%+.4 V
0.5%+.25 V
1.8%+.4 V
1.2%+.30 V
2.5%+.5 V