Table 59: Chassis Component Alarm Conditions On Ex3200 Switches - Juniper EX3200 Hardware Manual

Hide thumbs Also See for EX3200:
Table of Contents

Advertisement

Copyright © 2016, Juniper Networks, Inc.

Table 59: Chassis Component Alarm Conditions on EX3200 Switches

Chassis
Component
Alarm Condition
Power
A power supply has
supplies
been removed from
the chassis.
An unknown power
supply is installed.
The power supply is
offline or the power
supply output has
failed.
Fan tray
Fan tray is not
installed.
One fan in the
chassis is not
spinning or is
spinning at below
the required speed.
Fan failure–i2c read
failure.
Chapter 21: Alarms and Syslog Messages
Alarm
Severity
Remedy
Minor
Install a power supply.
(yellow)
Minor
Install a power supply recommended by
(yellow)
Juniper Networks.
Major
Open a support case using the Case
(red)
Manager link at
http://www.juniper.net/support/
1-888-314-5822 (toll-free within the United
States and Canada) or 1-408-745-9500
(from outside the United States).
Minor
Install the fan tray.
(yellow)
Major
Check the fan.
(red)
Replace the faulty fan tray.
If the above two checks show no
problems, open a support case using the
Case Manager link at
http://www.juniper.net/support/
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Major
Check the fan.
(red)
Replace the faulty fan tray.
If the above two checks show no
problems, open a support case using the
Case Manager link at
http://www.juniper.net/support/
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
or call
or
or
221

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX3200 and is the answer not in the manual?

Questions and answers

Table of Contents