Chapter 5 Commands; Command List - YOKOGAWA wt1600 User Manual

Digital power meter
Hide thumbs Also See for wt1600:
Table of Contents

Advertisement

Chapter 5 Commands

5.1

Command List

Command
AOUTput Group
:AOUTput?
:AOUTput:HARMonics?
:AOUTput:HARMonics:CHANnel<x>
:AOUTput:NORMal?
:AOUTput[:NORMal]:CHANnel<x>
:AOUTput[:NORMal]:IRTime
COMMunicate Group
:COMMunicate?
:COMMunicate:HEADer
:COMMunicate:LOCKout
:COMMunicate:OPSE
:COMMunicate:OPSR?
:COMMunicate:OVERlap
:COMMunicate:REMote
:COMMunicate:STATus?
:COMMunicate:VERBose
:COMMunicate:WAIT
:COMMunicate:WAIT?
CURSor Group
:CURSor?
:CURSor:BAR?
:CURSor:BAR:POSition<x>
:CURSor:BAR[:STATe]
:CURSor:BAR:{Y<x>|DY}?
:CURSor:TRENd?
:CURSor:TRENd:POSition<x>
:CURSor:TRENd[:STATe]
:CURSor:TRENd:TRACe<x>
:CURSor:TRENd:{X<x>|Y<x>|DY}?
:CURSor:WAVE?
:CURSor:WAVE:PATH
:CURSor:WAVE:POSition<x>
:CURSor:WAVE[:STATe]
:CURSor:WAVE:TRACe<x>
:CURSor:WAVE:{X<x>|DX|PERDt|Y<x>|DY}?
IM 760101-11E
Function
Queries all settings related to the D/A output.
Queries all settings related to the D/A output for harmonic measurement.
Sets the D/A output items for harmonic measurement or queries the current
setting.
Queries all settings related to the D/A output for normal measurement.
Sets the D/A output items for normal measurement or queries the current
setting.
Sets the rated time of D/A output for integration for harmonic measurement
or queries the current setting.
Queries all settings related to communications.
Sets whether or not to be added a header to the response to a query or
queries the current setting.
Sets or clears local lockout.
Sets the overlap command that is to used by the *OPC, *OPC?, and *WAI
commands or queries the current setting.
Queries the operation pending status register.
Sets the commands that will operate as overlap commands or queries the
current setting.
Sets remote or local.
Queries line-specific status.
Sets the response messages to full form or abbreviated form or queries the
current setting.
Waits for a specified extended event.
Creates the response that is returned when the specified event occurs.
Queries all settings related to the cursor measurement.
Queries all settings related to the cursor measurement on the bar graph.
Sets the cursor position (order) on the bar graph or queries the current
setting.
Turns ON/OFF the cursor display on the bar graph or queries the current
setting.
Queries the cursor measurement value on the bar graph.
Queries all settings related to the cursor measurement on the trend.
Sets the cursor position on the trend or queries the current setting.
Turns ON/OFF the cursor display on the trend or queries the current setting. 5-19
Sets the cursor target on the trend or queries the current setting.
Queries the cursor measurement value on the trend.
Queries all settings related to the cursor measurement on the waveform
display.
Sets the cursor path on the waveform display or queries the current setting.
Sets the cursor position on the waveform display or queries the current
setting.
Turns ON/OFF the cursor display on the waveform display or queries the
current setting.
Sets the cursor target on the waveform display or queries the current setting. 5-19
Queries the cursor measurement value on the waveform display.
Page
5-12
5-12
5-12
5-13
5-13
5-13
5
5-14
5-14
5-14
5-15
5-15
5-15
5-15
5-15
5-15
5-15
5-16
5-18
5-18
5-18
5-18
5-18
5-18
5-18
5-19
5-19
5-19
5-19
5-19
5-19
5-19
5-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents