Command
:WAVeform:SRATe?
:WAVeform:STARt
:WAVeform:TRACe
:WAVeform:TRIGger?
WSETup (Wave SETup) Group
:WSETup?
:WSETup:POSition?
:WSETup:POSition:{UALL|IALL}
:WSETup:POSition:{U<x>|I<x>}
:WSETup[:SAMPling]
:WSETup:TDIV
:WSETup:TRIGger?
:WSETup:TRIGger:LEVel
:WSETup:TRIGger:MODE
:WSETup:TRIGger:SLOPe
:WSETup:TRIGger:SOURce
:WSETup:VZoom?
:WSETup:VZoom:{UALL|IALL}
:WSETup:VZoom:{U<x>|I<x>}
Common Command Group
*CAL?
*CLS
*ESE
*ESR?
*IDN?
*OPC
*OPC?
*OPT?
*PSC
*RST
*SRE
*STB?
*TRG
*TST?
*WAI
IM 760101-11E
Function
Queries the sampling rate of the retrieved waveform.
Sets the output start point of the waveform display data that is transmitted by
":WAVeform:SEND?" or queries the current setting.
Sets the target waveform for the WAVeform:SEND and WAVeform:LENGth
commands or queries the current setting.
Queries the trigger position of the retrieved waveform.
Queries all settings related to the waveform observation.
Queries all settings related to the vertical position (GND position) of the
waveform.
Collectively sets the vertical position (level of the center position) of the
waveform {voltage|current} of all elements.
Sets the vertical position (level of the center position) of the waveform
{voltage|current} of the element or queries the current setting.
Turns ON/OFF the waveform sampling or queries the current setting.
Sets the Time/div value of the waveform or queries the current setting.
Queries all settings related to the trigger.
Sets the trigger level or queries the current setting.
Sets the trigger mode or queries the current setting.
Sets the trigger slope or queries the current setting.
Sets the trigger source or queries the current setting.
Queries all settings related to the vertical zoom factor of the waveform.
Collectively sets the vertical zoom factor of the waveform
{voltage|current} of all elements.
Sets the vertical zoom factor of the waveform {voltage|current}
of the element or queries the current setting.
Executes zero calibration (zero level compensation, same operation as
pressing CAL (SHIFT+MEASURE)) and queries the result.
Clears the standard event register, extended event register, and error queue. 5-88
Sets the standard event enable register or queries the current setting.
Queries the standard event register and clears the register.
Queries the instrument model.
Sets a "1" to bit 0 (OPC bit) of the standard event register upon the
completion of the specified overlap command.
ASCII code "1" is returned when the specified overlap command is completed. 5-89
Queries the installed options.
Sets whether to clear the following registers at power up or queries the current
setting. Clears the register when the value rounded to an integer is not zero. 5-89
Executes the initialization of settings.
Sets the service request enable register or queries the current setting.
Queries the status byte register.
Executes the same operation as when SINGLE (SHIFT+HOLD) is pressed.
Performs a self-test and queries the result.
Holds the subsequent command until the completion of the specified overlap
operation.
5.1 Command List
Page
5-84
5-84
5-84
5-84
5-86
5-86
5-86
5
5-86
5-86
5-86
5-86
5-86
5-86
5-86
5-87
5-87
5-87
5-87
5-88
5-88
5-89
5-89
5-89
5-89
5-89
5-90
5-90
5-90
5-90