YOKOGAWA wt1600 User Manual page 63

Digital power meter
Hide thumbs Also See for wt1600:
Table of Contents

Advertisement

:DISPlay:TRENd:NORMal:ITEM<x>:SCALing:
VALue
Function
Sets the upper and lower limits of manual
scaling of the trend for normal measurement or
queries the current setting.
Syntax
:DISPlay:TRENd:NORMal:ITEM<x>:
SCALing:VALue {<NRf>,<NRf>}
:DISPlay:TRENd:NORMal:ITEM<x>:
SCALing:VALue?
<x> = 1 to 16 (item number)
<NRf> = –9.9999E+30 to 9.9999E+30
Example
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:VALUE 100,-100
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:VALUE? ->
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:VALUE 100.00E+00,
-100.00E+00
Description • Set the upper limit and then the lower limit.
• This command is valid when the scaling
mode of the trend (:DISPlay:TRENd:
NORMal:ITEM<x>:SCALing:MODE) is set to
"MANual."
:DISPlay:TRENd:PDIV
Function
Sets the horizontal axis (Point/div) of the trend
or queries the current setting.
Syntax
:DISPlay:TRENd:PDIV {<NRf>}
:DISPlay:TRENd:PDIV?
<NRf> = 1, 2, 5, 10, 20, 50, 100, 200, 500
Example
:DISPLAY:TREND:PDIV 50
:DISPLAY:TREND:PDIV? -> :DISPLAY:
TREND:PDIV 50
Description This command is valid when waveform
sampling (:WSETup[:SAMPling]) is on during
normal measurement or during harmonic
measurement.
:DISPlay:TRENd:RESTart
Function
Restarts the trend.
Syntax
:DISPlay:TRENd:RESTart
Example
:DISPLAY:TREND:RESTART
:DISPlay:TRENd[:SAMPling]
Function
Turns ON/OFF the trend waveform sampling or
queries the current setting.
Syntax
:DISPlay:TRENd:
[:SAMPling] {<Boolean>}
:DISPlay:TRENd:[:SAMPling]?
Example
:DISPLAY:TREND:SAMPLING ON
:DISPLAY:TREND:SAMPLING? ->
:DISPLAY:TREND:SAMPLING 1
IM 760101-11E
:DISPlay:TRENd:TDIV
Function
Sets the horizontal axis (T/div) of the trend for
normal measurement or queries the current
setting.
Syntax
:DISPlay:TRENd:TDIV {<NRf>,<NRf>,
<NRf>}
:DISPlay:TRENd:TDIV?
{<NRf>, <NRf>, <NRf>} = 0, 0, 3 to 24, 0, 0
1st <NRf> = 1, 3, 6, 12, 24 (hour)
2nd <NRf> = 1, 3, 6, 10, 30 (minute)
3rd <NRf> = 3, 6, 10, 30 (second)
Example
:DISPLAY:TREND:TDIV 0,0,3
:DISPLAY:TREND:TDIV? -> :DISPLAY:
TREND:TDIV 0,0,3
Description • Set the three <NRf>'s so that one <NRf> is a
non-zero value and the other two are zeroes.
• This command is valid when waveform
sampling (:WSETup[:SAMPling]) is set to
OFF.
:DISPlay:TRENd:T<x>
Function
Turns ON/OFF the trend or queries the current
setting.
Syntax
:DISPlay:TRENd:T<x> {<Boolean>}
:DISPlay:TRENd:T<x>?
<x> = 1 to 16 (item number)
Example
:DISPLAY:TREND:T1 ON
:DISPLAY:TREND:T1? ->
:DISPLAY:TREND:T1 1
:DISPlay:VECTor?
Function
Queries all settings related to the vector display.
Syntax
:DISPlay:VECTor?
Example
:DISPLAY:VECTOR? -> :DISPLAY:
VECTOR:NUMERIC 1;UMAG 1.000;
IMAG 1.000
:DISPlay:VECTor:NUMeric
Function
Turns ON/OFF the numerical data display for
the vector display or queries the current setting.
Syntax
:DISPlay:VECTor:NUMeric {<Boolean>}
:DISPlay:VECTor:NUMeric?
Example
:DISPLAY:VECTOR:NUMERIC ON
:DISPLAY:VECTOR:NUMERIC? ->
:DISPLAY:VECTOR:NUMERIC 1
:DISPlay:VECTor:{UMAG|IMAG}
Function
Sets the zoom factor of the {voltage|current}
display during vector display or queries the
current setting.
Syntax
:DISPlay:VECTor:{UMAG|IMAG} {<NRf>}
:DISPlay:VECTor:{UMAG|IMAG}?
<NRf> = 0.100 to 100.000
Example
:DISPLAY:VECTOR:UMAG 1
:DISPLAY:VECTOR:UMAG? -> :DISPLAY:
VECTOR:UMAG 1.000
5.5 DISPlay Group
5
5-29

Hide quick links:

Advertisement

Table of Contents
loading