Specifications

This chapter describes the general, power supply, and performance specifications for the 3A-ADP.
2.1
Generic Specifications
Item
Ambient
temperature
Relative humidity
Vibration
*1
resistance
*1
Shock resistance
Noise resistance
Dielectric withstand
voltage
Insulation
resistance
Grounding
Working
environment
Working altitude
*1.
The criterion is shown in IEC61131-2.
*2.
If 3A-ADP is connected to the FX
*3.
PLC
Independent grounding
Best condition
*4.
If the pressure is higher than the atmospheric pressure, do not use the 3A-ADP.
The 3A-ADP may malfunction.
2.2
Power Supply Specifications
Item
Conversion circuit driving
power
Interface driving power
PLC User's Manual - Analog Control Edition
0 to 55 °C (32 to 131 °F) when operating
-25 to 75 °C (-13 to 167 °F) when stored
5 to 95 %RH (no condensation) when operating
Frequency
(Hz)
10 to 57
DIN Rail Mounting
57 to 150
10 to 57
*2
Direct Mounting
57 to 150
2
147 m/s
Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z
Using noise simulator of:
Noise voltage: 1,000 Vp-p / Noise width: 1 μs / Rise: 1 ns / Cycle: 30 to 100 Hz
500 V AC, for 1 min
5 MΩ or more using 500 V DC
insulation resistance meter
Class D grounding (grounding resistance: 100 Ω or less)
<Common grounding with a heavy electrical system is not allowed.>
Free from corrosive or flammable gas and excessive conductive dusts
*4
< 2000 m
/FX
3GC
Other
Other
PLC
equipment
equipment
Shared grounding
Good condition
→ For a detailed description of the grounding, refer to Section 3.5.
24 V DC +20 %-15 %, 90 mA
(It is necessary to connect a 24 V DC power line to the terminal block.)
5 V DC, 20 mA
(Since the internal power is supplied from the main unit of the FX Series, it is not
necessary to supply the power.)
Specifications
Acceleration
Half amplitude
2
(m/s
)
-
4.9
-
9.8
Between all terminals and ground terminal
Series PLC, direct installation is not possible.
3UC
Other
PLC
equipment
Common grounding
Not allowed
Specifications
2 Specifications
2.1 Generic Specifications
(mm)
Tests 10 times in each
0.035
direction (X-, Y-, and Z-
axis directions) (Total:
-
80 min, each)
0.075
-
*3
A
B
C
D
E
F
G
H
I
J
H-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3sFx3gcFx3uFx3uc

Table of Contents