FX
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
FX
-4DA-ADP (4-channel Analog Output)
3U
3. Example of program 2 (For FX
For example, create the following program to change the digital output data (D100) of the 1st analog special
adapter.
M8001
Normally
OFF
FNC230
D100
LD>=
M10
F-28
PLC User's Manual - Analog Control Edition
3UC
/FX
3S
FNC237
K0
AND<=
FNC 22
MUL
FNC 23
DDIV
FNC 20
ADD
FNC 12
MOV
5.1 Example: Changing of Voltage Output Characteristics
/FX
Series PLC)
3G
3GC
M8280
M8284
D100
M10
K10000
D100
K1600
D101
D101
K10000 D103
D103
K400
D107
D107
D8280
5 Changing of Output Characteristics
Sets the output mode of channel 1 to the
voltage output mode.
Sets the output holding function for
channel 1.
Check to make sure the digital
value (D100) is in range.
Calculation for changing output
characteristics.
Stores the operation result in D8280.