Examples uses of table output function

[Uses of table output function]
• Inverter frequency setting, servo speed control, etc.
1. Inverter frequency setting
The output frequency can be controlled by inputting analog signals (e.g. voltage from 0 to 10 V and current
from 4 to 20 mA) to inverter frequency setting signals.
The analog signals and output signals have the following proportional relationship.
Output
frequency
(Hz)
60
30
0
To control the frequency as shown below, where control the analog signal is proportional to the frequency use
the table output function.
Output
frequency
(Hz)
60
30
0
Example of table output
Output
voltage (V)
10
S-shaped
interpolation
5
Point 1
0
Output update
time at point 1
E-52
PLC User's Manual - Analog Control Edition
3UC
5
10V
Analog signal
Point 2
No interpolation
Output update
time at point 2
Point 3
S-shaped
interpolation
Point 4
Output update
time at point 3