1.4 FRESh AIR INTAkE

To ensure trouble-free operation the stove/fireplace must have the
necessary air available for combustion and this is provided through the
fresh air intake.
The fresh air intake must:
- have a total free cross section at least equal to the size given in the
paragraph "TECHNICAL DATA";
- be protected by a grille or suitable guard provided it does not reduce
the minimum recommended section;
- be in a position whereby it cannot be obstructed.
The airflow necessary for the fire may be obtained in different ways:
- through a fresh air intake direct into the room of installation;
- with ducting through pipes direct to the room of installation, increasing
the recommended minimum free cross section by at least 15%;
- from an adjacent room to the place of installation provided this air
flows freely through permanent apertures communicating with the
outside.
a
The adjacent room from which air is taken must not have a low
pressure compared to the exterior due to a counter draught
caused by the presence in that room of another appliance in
use or of a suction device.
The permanent apertures in the adjacent room must comply
with the requirements given above.
d
Combustion air must not be taken from adjacent rooms used
as a garage or a combustible materials store or for activities
posing a fire hazard.

1.5 INSTALLATION ENvIRONMENT

The appliance should be installed in a location which allows safe and convenient use as well as easy maintenance. If the product being installed
requires an electrical socket, the room must also be provided with an earthed power supply in accordance with current regulations.
The room where the appliance is to be installed must comply with the following requirements:
a
They must not be used as a garage, store for combustible material or for activities with a risk of fire.
a
They must not be in a vacuum in relation to the outside environment due to the effect of contrary draught caused by the presence in
the room where the fi replace is installed of another appliance or an extractor device.
a
Do not use two stoves, a fireplace and a stove, a stove and a wood-fired cooking range, etc. in the same environment, since the
draught of one could affect the draught of the other.
• Devices suitable for cooking food with relative hoods without an extractor fan may only be used in kitchens.
• Gas appliances of type C are allowed (refer to current legislation and regulations in the place of installation).
Fig. 12