AIR FLOW INTERLOCKS - The lamp fan vane switch is located within the lamp cooling compartment.
The extractor vane switch is located just inside the top duct on the projector lid. Check and, if necessary, clean
the switches to remove accumulated dust or dirt that could impede movement. Within the exhaust duct
connected at the top of the projector, adequate airflow must be maintained and routed away from the operating
area surrounding the projector (or any nearby projectors). Inspect regularly and confirm that 1) there are no
obstructions or kinks within the ducting, 2) all air intake areas of the projection head and ballast are
unobstructed, and 3) exhaust airflow at the top vent is 600 CFM. Make sure lamp wiring does not interfere with
vane switch operation. Refer to
LAMINAR AIRFLOW DEVICE (LAD) - Whenever checking/replacing the air filter on the side of the
projector, also visually check the small square laminar airflow device (LAD) just beyond the filter opening.
The LAD should be nearly white in color—if very dark (rare), it may have to be replaced by a qualified service
technician. Contact Christie or your dealer.
4.2

Lamp Replacement

NOTE: For this procedure you will need a compatible Christie Xenon CDXL or CXL lamp as shown in the
CP2000-XB User Manual (020-100163-xx)—never install a lamp intended for a different model or projector.
Warning! 1) Make sure to use the correct wattage lamp supplied by Christie. 2) Lamp replacement is to be
done by a qualified service technician only. 3) EXPLOSION HAZARD —Wear authorized protective clothing
whenever the lamp door is open! Never apply a twisting or bending force to the quartz lamp body.
BEFORE YOUR BEGIN
Read and follow all other general lamp precautions in
STEP 1 - Turn OFF the Projector
Allow the fans to run at least 10 minutes for cooling. Warning! Never attempt to remove the lamp when it is
hot. The lamp is under great pressure when hot and may explode, causing personal injury and/or property
damage. Allow to cool completely.
STEP 2 - Set Ballast Breaker
Set the ballast breaker (power switch) to OFF.
STEP 3 - Disconnect from AC
Disconnect projection head and ballast from AC supply. Warning! SHOCK HAZARD. Disconnect both
components from AC.
STEP 4 - Open Lamp Door
a. Open the lamp door.
b. With protective clothing and shield on, unlock the lamp door and open it. Refer back to Figure 2-21
Open Lamp Door and Cooling Compartment, on page 2-14. If desired, release the latch mecha-
nism to remove the door entirely.
STEP 5 - Open Cooling Compartment
Turn knob to open the inner lamp-cooling compartment and reveal the cathode end (–) of the lamp.
CP2000-XB Setup Guide