4 Maintenance
NOTE: The illustrations provided are to enhance the understanding of the written material. They are
graphical representations only and may not represent your exact projector model.
4.1

Maintenance and Cleaning

To help ensure optimized performance and reliability, regularly check electrical, optical and other
components as described below. Warning! SHOCK HAZARD. Disconnect projection head and
ballast from AC at BOTH wall breakers.

4.1.1 Electrical

Do the following every 60 days or 500 hours (always disconnecting from AC first):
• Check the contact surfaces of positive (anode) and cathode (negative) connections for cleanli-
ness. Clean electrical contact surfaces as necessary to prevent contact resistance from scorching
connectors.
• Verify that all electrical and lamp connections are tight.

4.1.2 Optical

Unnecessary cleaning of optics can be more harmful than helpful, increasing the risk of degrading
delicate coatings and surfaces. In this projector, check only the lens and lamp reflector—maintenance
of other optical components requires a qualified service technician. Check these components
periodically in a clean, dust-free environment using a high-intensity light source or flashlight. Clean
them only when dust, dirt, oil or other marks are obvious. Never touch an optical surface with your
bare hand—always wear latex lab gloves.

When to Check

LENS: A small amount of dust or dirt on the lens has minimal effect on image quality—to avoid the
risk of scratching the lens, clean the lens only if absolutely required. See
below.
LAMP REFLECTOR: Inspect the mirror surface (reflector) for cleanliness only during a lamp
replacement, when the lamp is out. If necessary, clean as described below—make sure to wear
protective clothing while inspecting or cleaning. Note that color variation on the reflector surface is
normal.

Supplies

For cleaning off dust and/or grease, you will need:
• Soft camel-hair brush
• Dust-free blower—filtered dry nitrogen blown through an anti-static nozzle.
• Dust-free lens tissue such as Melles Griot Kodak tissues (18LAB020), Optowipes (18LAB022) or
Kim Wipes or equivalent
CP2000-XB Setup Guide
020-100250-02 Rev. 1 (06-2009)
Section Cleaning the Lens
4-1