Section 3: Basic Operation

Trained Operators, Advanced Users, Administrators and Installers

In addition to the basic user rights shown in the Any User above, the TPC offers four distinct password-
protected levels of use (shown in shaded areas in Figure 3-1). Each has all of the rights of lower levels, plus
additional rights as described below:
• Trained Operators can also access the New Lamp function required when replacing the lamp.
• Advanced users can access two additional menus (Custom and Advanced) where they can define all
display setups and set the DVI processing path, configure 3D displays, optimize light output, record lamp
changes, activate test patterns and set certain system preferences.
• Administrators can also use four Admin submenus—Source, Screen, color Gamut and IP Config—to
define setup files as selectable choices for processing a variety of incoming signals. Source files set
incoming resolution, offset (rare) and desired final aspect ratio, Screen files determine image cropping
(masking), size of display area, and type of lens, and color Gamut information ensures color display stan-
dards are properly met in the current environment. In the IP Config menu, the administrator can define
new Ethernet settings (IP network addresses) for the projection head and TPC.
• Installers and other service personnel can access two additional configuration menus (General, and
Lamp) as well as three more Status submenus (Server, Diag and Interrogator). The installer can define
system operating parameters such as which projector is controlled by the TPC, and critical lamp parame-
ters such as installed lamp type, fan speed and light level at the screen. Installers can also establish temper-
ature scale preference, remote access rights, test pattern access rights, and extent of data logging. An
installer can see ID and error information for servers, as well as a detailed diagnostics log for in-depth trou-
bleshooting.

3.5.2 TPC Power-up Defaults

When the CP2000-XB powers up, the Touch Panel Controller will begin the steps of Initializing...,
Attempting to log on..., and Updating status, displaying its progress on the TPC status bar at the bottom of
the screen. When initializing is complete, all files are refreshed on the TPC and the system is in a ready-to-use
default operating mode:
• The Main menu appears on the Touch Panel Controller, where you can press the lamp button to turn on the
lamp.
• The most recently used channel button is depressed (darkened). Upon turning on the lamp, the image will
appear.

3.5.3 Failed TPC Connection

If the TPC fails to initialize and instead displays a communication error such as No connection or Cannot
locate Ethernet port or Waiting to Connect, there is likely a bad connection or address between the TPC and
the rest of the projector. Check that TPC cabling is intact, and try again. Review
if the problem persists, contact your network administrator.