Section 3: Basic Operation
OVER-TEMPERATURE
Card cage is too hot
Prism is too hot
Integrator is too hot
Red DMD is too hot
Blue DMD is too hot
SSM is too hot
Ballast is too hot and has shut down
OTHER FANS TOO SLOW
A primary fan is too slow or stopped
Card cage fan is too slow or stopped
Laminar airflow is too slow or stopped
LAMP PROBLEMS
Lamp Life has expired
Unexpected lamp off
Lamp strike failed
OTHER
SSM Communication Error
2
I
C Communication Error
LENS MOUNT
A communications error with the ILS motor con-
trol board has occurred. Please ensure that all
cabling is correctly connected.
ILS Motor Control Board - Sensor Failure
ILS Motor Control Board - In Boot/Program Mode
ILS Motor Control Board - Main Code CRC
* 1) A failed interlock automatically prevents power from going to the lamp and disables the lamp button on
the TPC Main menu. Since most interlock alarm conditions are triggered by switches, check the operation of
these switch levers. 2) When you have restored interlock integrity, the lamp button on the TPC Main menu is
automatically re-enabled.
3-8
Power down and cool projector. Ambient temperature may be too high. Check air filter
and fan.
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check air filter and sensor. Check liquid cooler fan.
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check air filter and sensor. Check liquid cooler fan.
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check fluid flow and level. Check air filter. Check liquid cooler fan.
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check fluid flow and level. Check air filter. Check liquid cooler fan.
Power down and cool projector. Reduce lamp power. Ambient temperature may be too
high. Check fluid flow and level. Check air filter.
Cool, then cycle the projector down-and-up normally. If the over-temp recurs, there is a
cooling problem in the ballast that may require service. Check ballast fan.
Replacement fan may be required.
Replacement fan may be required.
Replacement LAD filter or fan may be required.
Replacement of the lamp is recommended.
Increase Lamp Power. Check that DMDs have not overheated. An interlock may have
momentarily tripped. Lamp may have to be replaced.
If interlocks are OK, make sure the 220V connection near Panel C at the rear of the
projector head (on the underside) is still plugged in. If lamp re-try still fails, replace the
lamp.
Check cabling. Cycle projector power for a normal start-up. Check LEDs on card cage
boards, which can indicate a light engine problem instead. Check LVPS/Processor
voltages. Also, if shutter or lamp are functioning normally, SSM likely OK.
There may be a power problem with the main electronics (I
voltage adjustments.
Check cabling. Cycle projector power for a normal start-up.
This error will only be detected on a lens reset or lens calibrate. Check the sensors. It is
cleared by cycling the projector power or performing a lens reset.
If this message remains for longer than 4 seconds, try re-powering the TPC or upgrading
the MCB software.
Upgrade MCB software.
2
C). Check LVPS/Proc.
CP2000-XB Setup Guide