H-3 Is The System Power Led Green? - HP ProLiant DL580 Setup And Installation Manual

Generation 2 server
Hide thumbs Also See for ProLiant DL580:
Table of Contents

Advertisement

Table H-3: Is the System Power LED Green?
Answer
Possible Reasons
No, it is off
Power On/Standby button has not
been pressed firmly.
A power supply problem exists. The
power supply may not be connected or
inserted properly, it may have a
damaged connector, or it may have
failed.
The system may have experienced a
short.
The front panel LED assembly has
failed.
Yes
Note: For cabling configurations, refer to Appendix D, "Cabling Guidelines." For LED locations and
functions, refer to Appendix E, " System LEDs and Switches."
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide
Possible Solutions
Firmly press the power button.
Be sure that the power supply is
undamaged, the power supply is fully
seated, and the power supply LED is
green.
Check for bent connector pins and
improperly seated expansion boards.
Be sure that the front panel LED
assembly cable is connected to the
power backplane.
If these solutions do not solve the
problem, contact an authorized
service provider for assistance.
If the system power button LED is
green, refer to Table H-4.
Troubleshooting
H-7

Advertisement

Table of Contents
loading

Table of Contents