Is The System Power Led Green; Is The External Health Led Green - HP PROLIANT DL380 User Manual

Generation 3 server
Hide thumbs Also See for PROLIANT DL380:
Table of Contents

Advertisement

Is the System Power LED Green?

Answer
Possible Reasons
No
Power On/Standby button has not been
pressed firmly.
The power supply may not be inserted
properly, it may have a damaged
connector, or it may have failed.
The system may have experienced a
short.
The power converter module, system
board, SCSI backplane, and/or power
button/LED board may need to be
replaced.
The PCI riser cage is not fully seated.
Yes
If the system power LED is green, refer to "Is the External Health LED Green? (on page
135)."

Is the External Health LED Green?

Answer
Possible Reasons
No, it is
Power supply redundancy is lost due to a
amber
power supply failure.
No, it is
All installed power supplies have failed.
red
The system may have experienced a
short.
Yes
If the external health LED is green, refer to "Is the Internal Health LED Green? (on page
136)."
Server Specific Troubleshooting
Possible Solutions
Firmly press the Power On/Standby button.
Be sure that the power supply is undamaged
and is fully seated.
Be sure that all pins on connectors and
components are straight.
Reseat expansion boards.
Reseat the PCI riser cage.
Contact your authorized service provider for
assistance.
Possible Solutions
Be sure that the power supply is undamaged
and fully seated, or identify and replace the
failed power supply.
Contact your authorized service provider for
replacement parts and service.
Contact your authorized service provider for
replacement parts and service.