System LEDs and Switches
Table E-3: Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED
On
On
Flashing
Off
Off
Off
On or
flashing
E-4
Online
Fault
LED
LED
Off
Off
Flashing
Off
Flashing
Flashing
Off
Off
Off
On
On
Off
On
Off
HP ProLiant DL580 Generation 2 Server Setup and Installation Guide
Status
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the
Array Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
OK to replace the drive online if a predictive failure
alert is received (refer to "Hot-Plug Fan LED" for
details), and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
OK to replace the drive online.
The drive has failed and has been placed off-line.
OK to replace the drive online if a predictive failure
alert is received (refer to the following section for
details), provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is online and being accessed.