Hot-Plug Scsi Hard Drive Led Combinations - HP ProLiant DL360 Generation 4 Maintenance And Service Manual

Hp proliant dl360 generation 4 server
Hide thumbs Also See for ProLiant DL360 Generation 4:
Table of Contents

Advertisement

74
HP ProLiant DL360 Generation 4 Server Maintenance and Service Guide
Item
1
2
3

Hot-Plug SCSI Hard Drive LED Combinations

Activity
Online
LED (1)
LED (2)
On, off, or
On or off
flashing
On, off, or
On
flashing
On or
Flashing
flashing
On
Off
LED Description
Activity status
Online status
Fault status
Fault LED
Interpretation
(3)
Flashing
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
The drive is online and is configured as part of an array.
If the array is configured for fault tolerance and all other drives in the
array are online, and a predictive failure alert is received or a drive
capacity upgrade is in progress, you may replace the drive online.
Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding or undergoing capacity expansion.
Off
Do not remove the drive.
The drive is being accessed, but (1) it is not configured as part of an
array; (2) it is a replacement drive and rebuild has not yet started; or
(3) it is spinning up during the POST sequence.
Status
On = Drive activity
Flashing = High activity on the drive or drive
is being configured as part of an array.
Off = No drive activity
On = Drive is part of an array and is
currently working.
Flashing = Drive is actively online.
Off = Drive is offline.
On = Drive failure
Flashing = Fault-process activity
Off = No fault-process activity

Advertisement

Table of Contents
loading

Table of Contents