Hot-Plug Scsi Hard Drive Led Combinations - HP ProLiant DL360 SERIES User Manual

Hide thumbs Also See for ProLiant DL360 SERIES:
Table of Contents

Advertisement

20
HP ProLiant DL360 Generation 4p Server User Guide

Hot-Plug SCSI Hard Drive LED Combinations

Activity
Online
LED (1)
LED (2)
On, off, or
On or off
flashing
On, off, or
On
flashing
On or
Flashing
flashing
On
Off
Flashing
Flashing
Off
Off
Off
Off
Fault LED
Interpretation
(3)
Flashing
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
The drive is online and is configured as part of an array.
If the array is configured for fault tolerance and all other drives in the
array are online, and a predictive failure alert is received or a drive
capacity upgrade is in progress, you may replace the drive online.
Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding or undergoing capacity expansion.
Off
Do not remove the drive.
The drive is being accessed, but (1) it is not configured as part of an
array; (2) it is a replacement drive and rebuild has not yet started; or
(3) it is spinning up during the POST sequence.
Flashing
Do not remove the drive. Removing a drive may cause data loss
in non-fault-tolerant configurations.
Either (1) the drive is part of an array being selected by an array
configuration utility; (2) Drive Identification has been selected in
HP SIM; or (3) drive firmware is being updated.
On
The drive has failed and has been placed offline.
You may replace the drive.
Off
Either (1) the drive is not configured as part of an array; (2) the drive
is configured as part of an array, but it is a replacement drive that is
not being accessed or being rebuilt yet; or (3) the drive is configured
as an online spare.
If the drive is connected to an array controller, you may replace the
drive online.

Advertisement