Hot-Plug Scsi Hard Drive Led Combinations - HP ProLiant DL585 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL585:
Table of Contents

Advertisement

Server Component Identification
Table 4-8: Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED
On
On
Flashing
Off
Off
Off
On or
flashing
4-10
Online LED
Fault
LED
Off
Off
Flashing
Off
Flashing
Flashing
Off
Off
Off
On
On
Off
On
Off
Status
Do not remove the drive. Removing a drive during
this process will cause data loss.
The drive is being accessed and is not configured as
part of an array.
Do not remove the drive. Removing a drive during
this process will cause data loss.
The drive is rebuilding or undergoing capacity
expansion.
Do not remove the drive. Removing a drive during
this process will cause data loss.
The drive is part of an array being selected by the
Array Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
OK to replace the drive online if a predictive failure
alert is received, and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
OK to replace the drive online.
The drive has failed and has been placed off line.
OK to replace the drive online if a predictive failure
alert is received, provided that the array is configured
for fault tolerance and all other drives in the array are
online.
The drive is online and configured as part of an array.
Do not remove the drive. Removing a drive during
this process will cause data loss.
The drive is online and being accessed.
HP ProLiant DL585 Server Maintenance and Service Guide