Acura 1994 Integra Service Manual page 1064

Hide thumbs Also See for 1994 Integra:
Table of Contents

Advertisement

Recirculation Control Motor
Test
Connect baftery power to the No. 1 terminal of the
recirculation control motor, and connect ground to
the No. 2 and No. 4 terminals; the recirculation con-
trol motor should run smoothly.
Disconnect the ground from the No. 2 or No. 4 ter-
minals; the recirculation control motor should stoo
at FRESH or RECTRCULATE.
CAUTION: N6v€r conn€ct the batt6ry in ths oppo-
aite direction.
NOTE: Don't cycle the recirculation control motor
for a long time.
It the recirculation conttol motot does not run in steD
'1,
remove it, and check the recirculation control link-
age and door for smooth movement. lf the recircu-
lation control linkage and doo. move smoothly,
replace the recirculation control motor.
Replacement
Disconnect the 4P connector from the recirculation
control motor, and remove the wire harness clio from
it.
Remove the two screws, recirculation cont.ol mo,
tor and flange collar.
SCREWS
REC|RCULAT|OII
CONTROL MOTOR
3. Instsll in the reverse order of removal. After instal-
lation, make sure tha tecirculation control motor runs
smoothlv.
4P CONNECTOR
21-29

Hide quick links:

Advertisement

Table of Contents
loading