Troubleshooting
Reference Ghart
. Any abnormality must be correctsd before continuing the test.
.
Because of the precise measurgments needed, use a multimeter when testing.
Before performing any troubleshooting procedures check:
.
Fus€s .r No. 35120 A), *1 No. 33 (20 A), ), No. 13(7.5A)
. G r o u n d s N o . G 4 0 1 , G 2 0 1 , G ' 1 5 1 , G 1 0 1
. Cleanliness and tightness of all connectors
*1: In the under-hood fuse/relay box
*2: In the under-dash fuse/relay box
SYMPTOM
REMEDY
Radiator fan does not run 8t all.
Perform the procedures in the flowchan (see page 22-8).
Condenser fan does not run at all.
Perform the procedures in the flowchart (see page 22-10).
Both fans (radiator and condenser) do not
run for engine cooling, but they both run
with the Ay'C on.
Perform the procedures in the flowchan (see page 22-12).
Eoth fans do not run at all.
Perform the procedures in the flowchart (see page 22-13).
Compressor clutch does not engage.
Perform the procedures in the flowchart (see page 22-14).
Ay'C system does not come on
{compressor and both fans}.
Perform the procedures in the flowchart (see page 22-16).
22-7