General Troubleshooting Checklist - Bodyguard T-30 User Manual

Table of Contents

Advertisement

a) Electrodes not wet enough
Erratic
b) Interference from other signals
Reading
c) HR Receiver problem
8.7

GENERAL TROUBLESHOOTING CHECKLIST

PROBLEM
Display will not
No Power from wall
light up when the
socket
power switch is
turned on and
Faulty Power cord
THERE ARE NO
LIGHTS on the
Faulty Switch
Motor Control
Board under the
Tripped Circuit Breaker
motor cover
indicating that
Faulty component or
there is a
wiring before the
problem before
M.C.B.
or at the M.C.B.
Damaged motor control
board.
Table 2 – General Troubleshooting Checklist
POSSIBLE CAUSE
a) Moisten electrodes with water
b) Move machine away from potentials
sources of interference (or turn them
off) such as radios, neon or
fluorescent lightning, dog fences etc.
c) Use Diagnostics Menu to check signal
(See Heart Rate Test at section 6.6)
Ensure there is power from the wall socket by testing
there is 120 VAC with multimeter or plugging a lamp
into the wall socket and confirming it works. If there is
no power, try a different wall socket, check if the
house's circuit breaker needs to be reset or contact an
electrician.
Check if the power cord is passing 120 VAC of power
when it is plugged into a functioning wall socket. If not,
replace.
If 120 VAC is entering the treadmills power plug confirm
if the Power Switch lights up when turned on, replace if
necessary.
Push the circuit breaker in to reset it. If it has tripped
multiple times it may be permanently damaged and
require replacing.
Check all other components and wiring before the
M.C.B. for 120 VAC to see at which point the power is
stopping. This will identify the damaged component or
where the wiring has been incorrectly attached.
Test if 120 VAC is entering the M.C.B. with a
multimeter. Make a circuit with the multimeter probes
and the two wires that connect to the M.C.B. at ACN &
ACL. If there is 120 VAC then the M.C.B. is receiving
the correct power indicating all the previous
components in the series are functioning correctly
therefore the problem is with the M.C.B. as it is not
lighting up.
72
TREADMILLS – USER MANUAL
SOLUTION

Hide quick links: