Wireless Heart Rate System - Bodyguard T-30 User Manual

Table of Contents

Advertisement

lights being too close to the
console or a dog fence
f) Damaged CHR Board in
console
g) Display damaged
8.6.2

WIRELESS HEART RATE SYSTEM

To diagnose any problems with the Wireless Heart Rate System, please refer to table 1.2.
NOTE – Only compatible 5kHz wireless chest strap transmitters will function with Bodyguard's
Wireless Heart Rate receiver.
The Wireless Heart Rate System is made up of four parts; the compatible 5kHz Wireless Chest Strap
Transmitter the user attaches to their chest, Bodyguard's Wireless Heart Rate Receiver in the
treadmill, the cable that connects the Wireless Heart Rate Receiver to the Display and the Display.
Table 1.2 – Wireless Heart Rate Troubleshooting Checklist
PROBLEM
a) Non-compatible chest strap transmitter
(e.g. incorrect frequency or Bluetooth)
No Reading
b) Dead battery in chest strap transmitter
c) Dry electrodes on chest strap
d) HR Receiver problem
a) Weak battery
b) Electrodes not wet enough
Weak
c) Poor skin contact
Reading
d) Too much body fat
e) HR Receiver problem
POSSIBLE CAUSE
TREADMILLS – USER MANUAL
d) No Solution for Contact Heart Rate, try the
wireless chest transmitter as the pulse is
usually stronger in the chest area.
e) Move equipment out of range of interfering
force or disable it.
f) Change CHR board in console
g) Replace Display
a) Use Polar compatible (5kHz) chest
strap transmitter.
b) Replace battery
c) Moisten Electrodes with water
d) Use the Diagnostics Menu to check
the signal (See Heart Rate Test in
section 6.6)
a) Replace battery
b) Moisten electrodes with water
c) Adjust chest strap to get a tight fit on
the skin
d) No solution
e) Use Diagnostics Menu to check signal
(See Heart Rate Test in section 6.6)
71
SOLUTION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-45T-75

Table of Contents