Connecting Cables to the Patch Panel

If you are using the optional patch panel, use this procedure to connect the
cables to WFC:
1. Plug the RJ21-end of the cable assembly into the telephony connector.
2. Plug the other end of the cable assembly into the patch panel header.
3. The cable locks in place.
4. Connect the wires (digital telephones, analog telephones, and analog
trunks) to the patch panel.
5. Connect cables to the BCM50 as required.

Reset Button

The BCM Reset button performs two functions:
1. Initialises a graceful reboot
2. Performs an immediate reboot
To access the reset button, you will need a thin, non-metallic object.

Graceful Reboot

Initialising a graceful reboot is the preferred hardware reboot option. The
reboot process can be started safely, without loss of data.
1. Using the thin, non-metallic object, press and hold the reset button for
less than 5 seconds.
2. The reboot process will begin when the system is ready.