Asm8(+)/Gasm/Dsm(+) Media Bay Module Amphenol Wiring - Avaya BCM50 Hardware Installation Manual

Hide thumbs Also See for BCM50:
Table of Contents

Advertisement

Note: The wiring scheme relates to the main unit amphenol connection only. If
connecting to a station media bay module (e.g. DSM 16+/32+), the first
extension is wired to the first device pair in the table above (i.e. Blue/White).

ASM8(+)/GASM/DSM(+) Media Bay Module Amphenol Wiring

Use the table below if connecting extensions (stations) to a DSM Media Bay
Module.
Device
Pin
Connection Wire Colour
1
26
Tip
1
Ring
2
27
Tip
2
Ring
3
28
Tip
3
Ring
4
29
Tip
4
Ring
5
30
Tip
5
Ring
6
31
Tip
6
Ring
7
32
Tip
7
Ring
8
33
Tip
8
Ring
9
34
Tip
9
Ring
10
35
Tip
10
Ring
11
36
Tip
11
Ring
12
37
Tip
12
Ring
13
38
Tip
13
Ring
14
39
Tip
14
Ring
15
40
Tip
15
Ring
16
41
Tip
16
Ring
17 - 25
No Connection
Note: The ASM8/8+ and GASM MBM's support 8 analog stations.
NN40011-002 Issue 1.2 BCM50 Rls 6.0
Expansion Port 1
ASM8/GASM
DSM16/
DSM 32 Low
Default DN's
ASM8/GASM/DSM
White-Blue
237
Blue-White
White-Orange
238
Orange-White
White-Green
239
Green-White
White-Brown
240
Brown-White
White-Slate
241
Slate-White
Red-Blue
242
Blue-Red
Red-Orange
243
Orange-Red
Red-Green
244
Green-Red
DSM Only
Red-Brown
245
Brown-Red
Red-Slate
246
Slate-Red
Black-Blue
247
Blue-Black
Black-Orange
248
Orange-Black
Black-Green
249
Green-Black
Black-Brown
250
Brown-Black
Black-Slate
251
Slate-Black
Yellow-Blue
252
Blue-Yellow
BCM50 Hardware & Installation
Expansion Port 2
DSM 32
ASM8/GASM
DSM 32
High
DSM 16/
High
Def. DN's
Def. DN's
DSM32 Low
Def. DN's
253
269
254
270
255
271
256
272
257
273
258
274
259
275
260
276
261
277
262
278
263
279
264
280
265
281
266
282
267
283
268
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
37

Advertisement

Table of Contents
loading

Table of Contents