Installing The Bcm50 Wall Mount Bracket - Avaya BCM50 Hardware Installation Manual

Hide thumbs Also See for BCM50:
Table of Contents

Advertisement

BCM50 Hardware & Installation
7. If you want to further secure the unit, use four of the self-tapping
screws supplied with the rack mount kit to attach the unit to the rack
mount shelf. Make sure the screw holes in the unit are aligned with the
holes in the rack mount shelf. Then drive the four screws through the
holes in the bottom of the shelf and into the screw holes in the bottom
of the unit.

Installing the BCM50 Wall Mount Bracket

1. Place the wall mount bracket on the backboard and mark the location
of the center keyhole-shaped screw hole on the plywood backboard
2. Install one #8 x 2 cm (#8 x 0.75 in.) round-head wood screw in the
backboard.
3. Do not tighten the screw head against the backboard. Leave
approximately 0.5 cm (0.25 in.) of the screw exposed from the
backboard.
4. Prepare the wall mount bracket by removing the alignment tabs: If this
is the only unit in the BCM50 system, remove the alignment tabs on the
right side of the wall mount bracket. If this is the last unit on BCM50
system with multiple units, remove the alignment tabs on the left side of
the wall mount bracket.
5. Hang the wall mount bracket on the mounting screw.
6. Use a level to make sure the wall mount bracket is level.
7. Install two #8 x 2 cm (#8 x 0.75 in.) round-head wood screws into the
screw holes in the wall mount bracket
8. Tighten the three wood screws against the wall mount bracket.
9. Open the cable management door.
10. Install two #8 x 2 cm (#8 x 0.75 in.) round-head wood screws into the
screw holes in the cable trough.
11. If the BCM50 system has more than one unit, place the additional wall
mount bracket on the backboard on the right side of the existing wall
mount bracket. Use the alignment tabs to ensure the two wall mount
brackets are properly aligned.
12. Use three #8 x 2 cm (#8 x 0.75 in.) round-head wood screws to secure
the wall mount bracket to the backboard
13. Open the cable management door.
20
NN40011-002 Issue 1.2 BCM50 Rls 6.0