Avaya BCM50 Hardware Installation Manual page 45

Hide thumbs Also See for BCM50:
Table of Contents

Advertisement

Power
Solid yellow
Solid yellow
Solid yellow
Solid green
Solid green
Solid green
Solid green
LED states seen during Safe Mode start up sequence
Solid red
Solid red
Solid red
LED states seen during shut down sequence or failure
Solid green
Off
Solid red
Solid red
Flashing red
Solid yellow
Off
Start-up Profile LED states (seen only during initial system install or staging)
Flashing Yellow
Solid Green
Flashing Yellow
Once the BCM50 has booted up and the BCM power and status lights are
solid green, the system start up process can then be commenced. Please
refer to the BCM50 System Start Up Guide for further details.
NN40011-002 Issue 1.2 BCM50 Rls 6.0
Status
LED status during Start up sequence
Solid yellow
Off
Solid yellow
Solid yellow
Flashing green
Solid green
Solid red
Solid green
Solid red
Flashing yellow
Flashing yellow
Solid yellow
Flashing yellow
Solid red
Solid red
Solid red
Off
Flashing Yellow
Solid Green
Flashing Red
BCM50 Hardware & Installation
Description
Power Applied to System
Power on self test (POST).
System initializing.
Kernel initialization or Safe
OS.
Services initializing.
Normal operation.
Services initialization failed.
System running with factory
default settings enabled.
System running in Software
Reset mode
System running in
Configuration Reset mode.
Graceful shutdown in
progress
Graceful shutdown
completed
Overheat detected. Thermal
shutdown completed
Power spike or Rail power
fluctuation detected.
Rail Power fluctuation. Power
Monitor Shutdown completed
Power spike shutdown
completed (temperature and
Rail power ok).
No power, system is shut
down (power cable is
disconnected)
Start-up Profile executing
Start-up Profile successfully
applied.
Start-up Profile failure.