BCM50 Hardware & Installation

Environment Checklist

The installation area must be:
 Minimum of 4 m (13 ft) from equipment such as photocopiers,
electrical
electromagnetic, radio frequency and electrostatic interference
 Within 1.5 m (5 ft.) of a three-wire grounded electrical outlet
 Clean, free of traffic and excess dust, dry and well ventilated
 Within the temperature ranges of 0°C and 40°C (32°F and 95°F)
 Between 20% and 80% non-condensing relative humidity
 Enough space and strength to support the BCM base unit
 Minimum of 46 cm (18 in.) from the floor
Note: The installation area must be of sufficient height from the floor to
prevent water damage.
You also need the following equipment to install a BCM50 unit:
 mounting hardware (either a rackmount shelf, a wallmount bracket
per unit or four rubber feet per unit)
 Phillips screwdriver #2
 flat blade screwdriver
 pliers
 antistatic grounding strap
 connecting tool
 surge protector (recommended)
 cables, 25-pair cable with RJ-21 connectors