■ Cleaning point

(1)
Cleaning rollers
After feeding 5,000 sheets, a large number of cards, or when using
carbon paper, wipe the rollers softly with a clean cloth slightly wetted with
disinfectant alcohol (ethanol).
* If the rollers are stained, the stains may rub off on cards or other various
malfunctions may occur.
(2)
Cleaning reading lens
Clean the reading lens by softly wiping it with a clean cloth slightly wetted
with disinfectant alcohol (ethanol) once a month or every 5,000 sheets.
* If the reading lens is stained, reading errors may occur.
(3)
Cleaning various sensors
Softly wipe the sensors with a clean cloth slightly wetted with disinfectant
alcohol (ethanol) once a month or every 5,000 sheets.
Use air blow etc. when cleaning the left skew sensor section.
*If the sensors are stained (with paper powder, etc.) detection errors may
occur.
Sheet detection sensor
Note)
*Cleaning intervals may differ depending on usage conditions
(usage frequency, quality of paper used, etc.)
*Use a solution of 1 part ethanol to 5 parts water as the diluted
disinfectant alcohol.