5.
5.4
DVD Module Error code
With DSW command 910 the set software can retrieve an
overview of all occurred engine errors.
5.4.1
Momentary Errors
Byte 0: latest error:
Overview of the BE error codes.
error
error
code
0x00
no_error
0x01
illegal_command_error
0x02
illegal_parameter_error
0x03
command_timeout_error
0x04
sledge_home_error
0x05
sledge_calibration_error
0x06
sledge_unstable_error
0x07
speed_timeout_error
0x08
speed_window_error
0x09
focus_timeout_error
0x0A
focus_retries_error
0x0B
focus_agc_error
0x0C
radial_timeout_error
0x0D
radial_retries_error
0x0E
radial_agc_error
0x0F
radial_init_error
0x10
hf_pll_error
0x11
wobble_pll_error
0x12
subcode_timeout_error
0x13
subcode_notfound_error
0x14
header_timeout_error
0x15
adip_timeout_error
0x16
adip_window_error
0x17
adip_sync_error
家电维修资料网,免费下载各种维修资料
DVDR615/69
Diagnostic Software
meaning
No error has occurred
Command not allowed in this
state or unknown command
Parameter(s) not valid for this
command
The maximum execution time for
the command has exceeded
The sledge could not be moved
home
An error occurred during calibra-
tion of the sledge
The sledge detected unstable
control
Spindle motor could not reach its
target speed within timeout
Measured spinning speed is not
within expected window
Focus could not be achieved
within the timeout
The amount of focus retries ex-
pired
The focus agc results are out of
range
Servo didn't get on track within
the timeout
Servo didn't get on track after
several retries
The radial agc results are out of
range
Unreliable signal scaling after the
radial initialisation
HF-decoder pll could not lock to
HF signal
Wobble pll could not lock to wob-
ble signal
Subcode information could not
be read
Requested subcode item could
not be found
Header information could not be
read
Adip information could not be
read
Adip address was not within ex-
pected window
No adip sync was detected
error
error
code
0x18
atip_timeout_error
0x19
atip_notfound_error
0x1A
atip_window_error
0x1B
atip_sync_error
0x1C
tray_error
0x1D
seek_error
0x1E
no_hf_present_error
0x1F
record_error
0x20
illegal_stopaddress_error
0x21
no_disc_error
0x22
not_initialised_error
0x23
illegal_medium_error
0x24
cd_frequency_error
0x25
dvd_frequency_error
0x26
re-
served(non_existing_bca_
error)
0x27
reserved(bca_read_error) An error occurred during reading
0x28
selftest_error
0x29
i2c_error
0x2A
laser_pll_error
0x2B
laser_forward_sense_erro
r
0x2C
jitter_optimisation_error
0x2D
tilt_calibration_error
0x2E
reserved
0x2F
frontend_offset_calib_erro
r
0x30
reserved
0x31
wsg_calculation_error
0x32
buffer_overrun_error
0x33
return_value_invalid_error The requested information is not
0x34
illegal_recording_speed_e
rror
0x35
opc_media_parameter_err
or
0x36
opc_record_power_error
0x37
opc_start_power_low_erro
r
0x38
opc_start_power_high_err
or
meaning
Atip information could not be
read
Requested atip item could not be
found
Atip address was not within ex-
pected window
No atip sync was detected
Tray could not be closed or
opened within the timeout
The requested seek couldn't be
performed within the timeout
Attempt to read from a blank area
An error occurred during the re-
cording
The requested stopaddress with
modify-stop-address is not valid
No disc is detected
The system is not initialised (e.g.
seek on unknown disctype)
BE detected an unsupported me-
dium during disc recognition
Measured HF frequency is not
within CD frequency range
Measured HF frequency is not
within DVD frequency range
Attempt to read non-existing bca
information
of bca information
An error occurred during the self-
test of the BE
The I2C interface does not oper-
ate
Laser control pll did not lock or
lost lock on write clock
Forward
sense
value
didn't
change with changing laser pow-
er
An error occurred during optimis-
ation of the jitter
An error occurred during calibra-
tion of the tilt frame
The offset in the frontend couldn't
be calibrated
An error occurred in the calcula-
tion of the write strategy
The buffer input stream overran
the buffer output stream
available for this inquiry
The selected speed is not al-
lowed for a recording on this me-
dium
The media parameters (info in
ATIP/ADIP) are invalid or not
read
The final optimum power was not
reached
OPC start power too low (opti-
mum power is higher)
OPC start power too high (opti-
mum power is lower)