Example
DS:> 303 DIAGNOSTICS 5 1 0x5a
030300: Section is modified successfully
Test OK @
Nucleus Name
DS_NVRAM_Read
Nucleus Number
304
Description
Read out one or more locations in the NVRAM
Technical
-
-
-
Execution Time
Less than 1 second
User Input
1. The location which must be read i.e. "ALL" "BOOT" "DIAGNOSTICS" "DOWN LOAD"
"CONFIG" "RECORDER" or no string if an offset from the base address of the NVRAM
is required
2.
<offset> <length>
Error
Number
30400
30401
30402
30403
30404
30405
30406
30407
30408
Example
304 DIAGNOSTICS 0 6
030400: Value read = 0x00 0x00 0x00 0x00 0x00 0x5A
Test OK @
SDRAM
Nucleus Name
DS_SDRAM_WriteRead
Nucleus Number
400
Description
Check all data lines, address lines and memory locations of the SDRAM
Technical
-
-
-
Execution Time
11 seconds for 32 Mb
23 seconds for 64 Mb
User Input
None
Error
Number
40000
40001
40002
40003
Example
DS:> 400
040000:
Test OK @
Nucleus Name
DS_SDRAM_WriteReadFast
Nucleus Number
401
Description
Check all data lines and address lines of the SDRAM
Technical
-
-
Execution Time
Less than 1 second
User Input
None
Error
Number
40100
40101
40102
Example
DS:> 401
040100:
Test OK @
家电维修资料网,免费下载各种维修资料
Diagnostic Software
Initialise IIC
Decode user input
Read from the NVRAM and return this info to the user
The offset and number of bytes to read
Description
Value read
Unable to initialise NVM
Reading the NVRAM contents failed
length out of range
unable to decode length
offset out of range
unable to decode offset
unknown location specified
no location is specified
Test the databus
Test the address bus
Test the integrity of the device itself (memory locations)
Description
The write-read test succeeded
The data bus contains an error
The address bus contains an error
The SDRAM itself contains an error
Test the databus
Test the addressbus
Description
The write-read test succeeded
The data bus contains an error
The address bus contains an error