Error
Number
190200
190201
Example
DS:> 1902
Hardware Version:0x 2, Revision Code :0x 7
MSP Product Code:0x19, ROM Version Code:0x48
190200:
Test OK @
Nucleus Name
DS_AMIX_Control
Nucleus Number
1903
Description
Test the controllability of the sound processor by performing a controlled reset
Technical
Test the control register, contains 0x80 after reset and 0x0 after first read of this control
register. MSP is reset and the control register is tested for the 0x80 reset indication
Execution Time
1 second
User Input
-
Error
Number
190300
190301
190302
Example
DS:> 1903
190300:
Test OK @
Note
European sets only !!
Nucleus Name
DS_AMIX_Beep
Nucleus Number
1904
Description
Test the beeper functionality of the sound processor
Technical
-
Execution Time
3 seconds
User Input
-
Error
Number
190400
190401
190402
190402
Example
DS:> 1904 ON
190400:
Test OK @
Nucleus Name
DS_AMIX_CommunicationAdcDac
Nucleus Number
1906
Description
This nucleus checks the communication between the IIC controller of the Codec and
the ADC/DAC chip (UDA 1380) on the analogue board
Technical
Test whether anything can be read from the ADC/DAC
Execution Time
Less than 1 second.
User Input
None
Error
Number
190600
190601
190602
190603
190604
190605
190606
Example
DS:> 1906
190600:
Test OK @
Nucleus Name
DS_AMIX_Mute
Nucleus Number
1907
Description
Set or unset the master mute of the ADC/DAC chip (UDA 1380) on the analogue board
家电维修资料网,免费下载各种维修资料
Diagnostic Software
Description
Getting the version info from the sound processor
succeeded
Getting the version info from the sound processor failed
Description
Testing the controllability succeeded
Accessing the MSP failed
Accessing the MSP succeeded, but wrong data was
returned
Description
Testing the beeper succeeded
Testing the beeper failed
There was an error routing the test path
The user provided the wrong input
Description
Communicating with the ADC/DAC succeeded
The IIC bus was not accessible
There was a timeout reading the device
The IIC acknowledge was not received
An IIC-bus error occurred
Got unknown IIC bus error
The IIC bus initialisation failed
DVDR615/69