Error
Number
90600
90601
90602
90603
90604
90605
90606
90607
90608
90609
Example
DS:> 906
090600: Testing on sector 0x5dbe0: OK
Test OK @
Nucleus Name
DS_BE_WriteReadDvdR
Nucleus Number
907
Description
Write data to and read data from a DVD+R disc through the basic engine for verification of
the writing
Technical
-
-
-
-
-
-
-
-
-
-
-
Execution Time
Approximately 20 seconds
User Input
None
Error
Number
90700
90701
90702
90703
90704
90705
90706
90707
90708
90709
90710
Example
DS:> 907
090700: Testing on sector 0x36210: OK
Test OK @
Nucleus Name
DS_BE_StatisticalInformationGet
Nucleus Number
908
Description
Retrieve the statistical information from the basic engine
Technical
-
-
-
-
Execution Time
Less than 1 second on AV2
2 seconds on AV3
User Input
None
家电维修资料网,免费下载各种维修资料
Diagnostic Software
Description
The command executed successfully
This nucleus cannot be executed because the Self-Test failed
The BE cannot enter normal operating mode
Unable to send the tray in
Unable to read TOC from disc
Invalid disc is loaded, please insert a DVD+RW disc
Writing the test pattern to DVD+RW failed
Reading back the test pattern from DVD+RW failed
Compare check failed
Calibrating DVD+RW failed
Check if an AV2 or AV3 is connected
Execute DS_BE_GetSelftestResults
Send the TRAY_IN command
Send the READ_TOC command
Use the OPC area to test if the DVD+R is (still) writable
Generate test data to write to the DVD+R
In case of an AV2 Transfer the test data to the disc location using DMA
In case of an AV3 Transfer the test data to the disc location using PIO mode ATAPI
WRITE_10
In case of an AV2 Read back the data from disc using DMA
In case of an AV3 Transfer the test data to the disc location using PIO mode ATAPI
READ_10
Compare the two data areas and check whether the areas are equal
Description
The command executed successfully
This nucleus cannot be executed because the Self-Test failed
The BE cannot enter normal operating mode
Unable to send the tray in
Unable to read TOC from disc
Invalid disc is loaded, please insert a DVD+RW disc
Unable to write, the DVD+R disc is full
No writable DVD+R sector found
Writing the test pattern to DVD failed
Reading back the test pattern from DVD failed
Compare check failed
Check if an AV2 or AV3 is connected
In case of an AV2 Send the S2B GET_STATISTICAL_INFO command
In case of an AV3 Send the transparent BIT engine GET_STATISTICAL_INFO
command
Display the info returned from the BE