Chapter 9 Operation and Maintenance
CPU mismatch detected
Available CPUs do not support the same bus
frequency- system halted
Baseboard Management Controller Error
Diskette drive A error
Diskette drive B error
Incorrect Drive A type - run SETUP
Incorrect Drive B type - run SETUP
System Cache Error - Cache disabled
Verify CPU Frequency selection in Setup
CPU runtime error (IERR#) detected
Correctable memory error in module X
Uncorrectable memory error in module X
Memory configuration has changed - Run
SETUP
No usable system memory
Memory module failed! This module is no
longer available for the operateing system.
258
table: List of POST Errors
Message
Description
The CPU frequency has changed.
If the correct CPU is installed and this message is displayed,
update the BIOS using the BIOS Update Utility supplied with
the CPU. If the message still appears after the update, select
[Yes] for the [Reset Configuration Data] setting on the
[Advanced] menu of the BIOS Setup Utility. If the message
still appears, the CPU or baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
BMC error. Power off the server and turn it back on. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
Floppy disk drive error. Check whether the floppy disk drive
cable is connected properly. Also check the settings of
[Diskette A] or [Diskette B] on the [Main] menu of the BIOS
Setup Utility.
System cache error. Power off the server and turn it back on. If
the message still appears, check the error log and replace the
CPU if it is faulty. Else, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
CPU error. Power off the server and turn it back on. If the
message still appears, check the error log and replace the CPU
if it is faulty. If the message still appears, the baseboard must
be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Installed CPU error. Check the error log and replace the CPU.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
Memory error. Check the error log and replace the memory
module. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
DRAM error. The DRAM size has changed since the last
startup. Check the error log and replace the memory module. If
the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
Memory error. No memory modules available to the system are
detected. Check the error log and replace the memory module.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide". After the replacement, enable the use of the memory in
the BIOS Setup Utility.
Memory error. Turn off the server and check whether the
memory module is installed correctly. If the message still
appears, check the error log and replace the memory module. If
the message still appears after the replacement, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".