Message
Memory decreases in Size
Hot Spare Memory Feature could not be
enabled
Non Fujitsu Siemens Memory Module detected
- Warranty restricted!
System battery is dead - Replace and run
SETUP
System CMOS checksum bad - Default
configuration used
System timer error
Real time clock error
Check date and time settings
Previous boot incomplete - Default
configuration used
CPU had been changed - Run SETUP
table: List of POST Errors
Memory error. Due to a memory failure, available memory
capacity is less than the capacity of the installed memory.
Check the error log and replace the faulty memory module. If
the message still appears after the replacement, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
The hot spare memory function cannot be enabled.
Check that all the installed memory modules are of the same
capacity. If the message still appears even though the
installation is correct, the memory module or baseboard must
be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Memory error. Check that the jumper pin settings and BIOS
Setup Utility settings are correct. If the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Battery error. Contact an office listed in the "Contact
Information" of "Start Guide".
The CMOS setting is invalid. Correct the current settings with
the BIOS Setup Utility or restore the settings to the initial
values. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
System clock error. Power off the server and turn it back on. If
the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
Real Time Clock (RTC) error. Start the BIOS Setup Utility and
enter the current time. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
The set date and time are invalid. Start the BIOS Setup Utility
and enter the current date and time. If the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
POST did not complete during the last startup. Be sure to
perform the following operation. Failure to do so can result in
the OS not starting or the server not operating correctly.
1. Start the BIOS Setup Utility.
2. From the [Exit] menu, select [Save Changes & Exit] and
press the [Enter] key.
The message "Save configuration changes and exit
now?" is displayed.
3. Select [Yes] and press the [Enter] key.
The BIOS Setup Utility closes and the server restarts.
The CPU has been replaced.
If the correct CPU is installed and this message is displayed,
select [Yes] for the [Reset Configuration Data] setting on the
[Advanced] menu of the BIOS Setup Utility. If the message
still appears, the CPU or baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
PRIMERGY TX150 S4 User's Guide