Adding The Ni-7932R To A Labview Project; Adding A Flexrio Adapter Module To The Target - National Instruments NI-7931 Getting Started Manual

Controller for flexrio
Table of Contents

Advertisement

7.
The recommended software set is preselected from the list of software add-ons. Check
any additional software add-ons you want. The System State Publisher, for example,
makes monitoring system performance simple.
Note
software add-ons later. The FlexRIO 15.0 Recommended Software Set is
enough to get started.
Click Next.
8.
9.
Review the summary of software to install. Click Next to begin the update.
10. Wait for the installation to finish, and then click Finish.

Adding the NI-7932R to a LabVIEW Project

Launch LabVIEW. The LabVIEW Getting Started window appears.
1.
2.
Click Create Project or open an existing project.
Right-click the project root in the Project Explorer window and select New»Targets
3.
and Devices from the shortcut menu to display the Add Targets and Devices dialog box.
a)
If the hardware is connected to the host, select Existing target or device. Select the
NI-7932R under Real-Time FlexRIO and click OK.
If the hardware is not connected to the host, select New target or device. Select the
b)
NI-7932R under Real-Time FlexRIO and click OK.
4.
Right-click the target and select New»FPGA Target.
The FPGA target appears in the project under the Real-Time target.

Adding a FlexRIO Adapter Module to the Target

Skip this section if you are not using an adapter module.
1.
Expand the FPGA target by clicking the + button, then right-click IO Module and select
Properties.
Select the General category and check the Enable IO Module box.
2.
3.
Select your I/O module from the IO Modules list, and select the CLIP you want to use
from the Component Level IP box.
Click OK.
4.
You can use the LabVIEW Real-Time Software Wizard to install more
NI-7932R Getting Started Guide | © National Instruments | 11