Error codes, part 2
Error # Error message shown in
the display
30
31
32
33
55
E55 WRONG S2N HW
CCD PORTS
56
Error 56: S2N Board: wrong
revision
60
Error 60: General camera
error
61
Error 61:
Camera 1 failed
62
Error 62:
Camera 2 failed
65
Error 65:
Camera 1 data bus error
66
Error 66:
Camera 2 data bus error
Page 102
Error message sent to
application
File format not supported.
Preview not possible
Invalid color conversion
No image available
Wrong S2N board detected
(not enough CCD ports)
Wrong S2N Board detected
(Revision not OK)
General camera error.
Camera 1 failed
Camera 2 failed.
Camera 1 data bus error.
Camera 2 data bus error.
Problem description
The specified file format is not
supported or it is invalid in
combination with the color mode.
The application specified an invalid
preview scale. Not all scale factors
are allowed with all image sizes.
The application changed the color
depth between scanning and image
transfer and a conversion between
these modes is not possible.
Example: scan in binary, then
changed color mode to truecolor.
The application attempted to get an
image from the scanner and there
was no scan since the device was
turned on.
The S2N board found is not the right
one for this device. Error can occur
after a repair/exchange. Exchange
with correct board.
The S2N board found is not the right
one for this device. Error can occur
after a repair/exchange. Exchange
with correct board.
General error on the CCD camera
board. Check power, cables and
S2N-PCI board.
Initializing of camera 1 failed. Check
power, cables and S2N-PCI board.
Initializing of camera 2 failed. Check
power, cables and S2N-PCI board.
Test data transfer to camera failed.
Check cables / connectors to camera
1 and S2N-PCI board.
Test data transfer to camera failed.
Check cables / connectors to camera
2 and S2N-PCI board.