Oki MC873dn Maintenance Manual page 59

Hide thumbs Also See for MC873dn:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Panel display
Cause
Inspection is
An abnormality
Does this error recur?
required.
was detected
231:Error xx
with the RFID
Reader
01 :
communication
error between
the RFID reader
and the engine
PCB.
02 : the
transceiver
circuit error of
the RFID reader.
03 :
communication
error between
the RFID reader
and the Tag chip.
04 : the RFID
Tag detection
error (more than
4 chips).
05 : K Reader
~ Tag Interface
connection error.
06 : Y Reader
~ Tag Interface
connection error.
07 : M Reader
~ Tag Interface
connection error.
08 : C Reader
~ Tag Interface
connection error.
11 : K Reader
detecting other
than K color Tag.
12 : Y Reader
detecting other
than Y color Tag.
13 : M Reader
detecting other
than M color Tag.
14 : C Reader
detecting other
than C color Tag.
45850101TH Rev.1
Check details
Result
Solution
Yes
Cycle the power.
01 to 03:Replace the RFID
reader board.
04:Remove the extra Tag chip.
05/11:Replace the Black toner
cartridge or image drum.
06/12:Replace the Yellow
toner cartridge or image
drum.
07/13:Replace the Magenta
toner cartridge or image
drum.
08/14:Replace the Cyan toner
cartridge or image drum.
Panel display
Cause
Check details
Inspection is
More than one
required.
image drum tag
Is more than one image
232:Error
of the same color
drum of the same color
was detected.
installed?
Inspection is
Secure File
required.
Erasing Error
250:Error
Inspection is
Secure disk
required.
Erasing Error
251:Error
Inspection is
An unexpected
required.
error occurred
254:Error
during
initialization in
the Security
mode.
Inspection is
An unexpected
required.
error occurred
257:Error
during
initialization of
the HDD.
Power OFF/ON
An unexpected
815:Error
error occurred at
FAX control.
Power OFF/ON
Short circuit
Is the belt thermistor
901:Error
with the belt
cable connected
thermistor was
properly?
detected.
Does this error recur
after power restoration?
Power OFF/ON
Open circuit
902:Error
with the belt
thermistor was
detected.
Power OFF/ON
Belt thermistor
Is the belt thermistor
903:Error
detected
cable connected
the high-
properly?
temperature.
Does this error recur?
Power OFF/ON
Belt thermistor
904:Error
detected the low-
temperature.
Power OFF/ON
Short circuit with
915:Error
the Duplex unit
thermistor was
detected.
Power OFF/ON
Open circuit with
916:Error
the Duplex unit
thermistor was
detected.
2. TROUBLESHOOTING PROCEDURES
Result
Solution
Cycle the power.
Yes
Replace the image drum.
Cycle the power.
No
Re-connect the cable
properly.
Yes
Replace the belt thermistor.
No
Re-connect the cable properly
and restore the power.
Yes
Replace the belt thermistor,
after a lapse of 30 minutes,
turn on the power.
Cycle the power.