Oki MC873dn Maintenance Manual page 50

Hide thumbs Also See for MC873dn:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
No. Category PJL Status
Panel messages
Code
97 Error
-
Please check data.
Program Data
Write Error
<%DLCODE%>
98 Error
40712
Inspection is
required.
%ERRCODE%:
SIP Error
99 Error
40724
Please call service.
Scanner unit failed
to detect printer
unit.
100 Error
40714
SIP Firmware
(ONLINE)
Missing
101 Fatal
40057
Power OFF/ON
070
%ERRCODE%:Error
073
%FATALSTRING1%
075
102 Fatal
40057
%ERRCODE%:Error
203
%FATALSTRING2%
204
45850101TH Rev.1
Description
Indicates that an error has happened while writing
the SIP download data.
%DLCODE%
1: Data transfer error
2: No device space
3: Check sum error
4: Chip detection error
5: Chip erace error
6: Chip writing error
7: Chip verify error
8: Data error (Product code is wrong e.t.c.)
9: Data size error
Indicates that the processing of Scan Image
Processing contller was failed.
User must turn Off/ On the power supply, if this
status occurred.
%ERRCODE%
4 digit hex code
Indicates that scanner and printer is not
connected.
This message is displayed, if the communication
between scanner and printer units could not be
started.
User must turn Off/ On the power supply, if this
status occurred.
Indicates that the firmware in board can not be
detected.
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
'%FATALSTRING1%' specifies error code that is
the detailed error cause.
The message of fatal error is specified by English
only.
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
'%FATALSTRING2%' specifies error code that is
the detailed error cause.
The message of fatal error is specified by English
only.
No. Category PJL Status
Panel messages
Code
103 Fatal
40057
Power OFF/ON
072
%ERRCODE%:Error
057
%CODE%
058
231
104 Fatal
40057
Power OFF/ON
209
%ERRCODE%:Download
Error
105 Error
30938
A decoding error
occurred.
Check the image
data.
106 Error
30930
Process has been
cancelled as
spooler is full.
Please free up
memory space by
reducing use and
try again.
107 Error
30932
Process has been
cancelled by a
spooler device
error.
Please contact
administrator.
108 Error
-
Access denied to
PC.
Please check PC.
2. TROUBLESHOOTING PROCEDURES
Description
A fatal error occurred.
For more information, see "Service Calls List."
%ERRCODE%: specifies 3 digits (decimal) error
code.
'%CODE%' specifies error code that is the
detailed error cause.
The message of fatal error is specified by English
only.
Downloading Media Table to PU has failed.
(Related to CustomMediaType.)
%ERRCODE%: specifies 3 digits (decimal) error
code.
The message of fatal error is specifiedby English
only.
"Download Error" is specified by Japanease and
English only.
Indicates that an error has occurred during
analysis of image data input to the MFP from an
external source.
This appears when an error has occurred during
analysis of TIFF or JPEG data in A05:DirectPrint,
A07: InternetFAX, E-mailPrint, or FaxToPrint
(saving sent/received data) mode.
Indicates that PC rejects a PushScan request.
(Select Close with the cursor and) press [OK]
button, and the display will return to ScanTo
standby screen.
(At present, screens to return to after errors have
been reset vary from function to function.
It is desirable to return to the same screen.)
2-25